Insulation

Insulation can be one of the most important factors in improving energy efficiency in a building. It slows the flow of heat through a building envelope. Insulation not only saves money by reducing heating and cooling loads but also is a key factor in achieving comfortable living and working spaces.

Insulation ratings

All insulation is rated according to its resistance to heat flow, measured in units of R-value in the United States. The inverse of thermal resistance is conductance, referred to as the U-value (U = 1/R), which in the United States is measured in units of Btu/square foot-°Fahrenheit-hour.

Whereas R-value is intuitively easier to understand (the higher the R-value, the better the insulating properties), U-value is more useful in calculations, because it describes the actual amount of heat that will move through the material for each degree Fahrenheit difference in temperature from one side of the material to the other. R-values of different components can be added (all the different layers of a wall, for example); U-values cannot be directly added (Figure 1).

Figure 1: Addition of R-values
What are the options?
this section

All common insulations use air or some other gas contained within bubbles or pockets in the insulation to decrease the insulation's conductivity, because a gas conducts heat more slowly than a solid. Also, to prevent convective heat loss, which occurs from the flow of gas, the gas must be kept as still as possible. The thin fibers in fiberglass insulation, for example, create small pockets of air and thus restrict air circulation. In theory, an inch of air can achieve an insulation value of R-5.5. Realistically, however, the best air-filled insulations only achieve R-4.5 to R-4.7 per inch (meaning that two inches of insulation would give you R-9 to R-9.4), and most are rated considerably lower. To achieve higher values, hydrofluorocarbons (HFCs) are used in place of air, because they have a lower conductivity.

There are three basic types of insulation: fiber, foam, and reflective.

Fiber insulation is available in either loose-fill form or in batts. Loose-fill insulation consists of fiberglass, cellulose, rock wool, or some other type of fibers that are blown into wall cavities or attic joist spaces. If properly installed, loose-fill insulation can provide more complete cavity coverage than batts, because the fibers can fill around wires, piping, and other obstacles. Loose-fill is usually installed by specialized contractors, whereas batts can be installed by nearly anyone with a desire to insulate a space. R-values per inch for loose-fill insulation range from R-2.2 for fiberglass to about R-3.2 for rock wool or cellulose.

Batts are available made of fiberglass, cotton, or rock wool, and all achieve an R-value of about R-3.2 per inch.

Be aware that loose-fill insulation can settle over time. When loose-fill insulation is located in a wall, its settling creates a void above the insulation that can serve as a conduit for heat. In an attic, settling results in a nonuniform distribution of the insulation, which can reduce its effectiveness. Some types of insulation use acrylic-based or other binders to help prevent settling, though there is some question as to how well they work.

Loose-fill cellulose can be mixed with water and blown in wet, usually without any added binders. This sticky mixture molds itself into gaps and seals them to a degree, which helps to eliminate air leakage and infiltration, and has an R-value of about R-3.5 per inch. Loose-fill cellulose can also be installed dry with a blowing machine and a reduced-size application nozzle that packs the insulation tightly, creating dense-pack, or high-density cellulose. Though this method does not seal as well as wet-spray cellulose, dense-pack cellulose also reduces air infiltration. Because it is packed tightly, little settling occurs and, unlike wet-spray cellulose, it can be used on wall insulation retrofits. It too has an R-value of around R-3.5.

Caveat emptor (Let the buyer beware)!

The effectiveness of any insulation is highly dependent on its proper installation. Although the Insulation Contractors Association of America is trying to combat the problem, improperly installed insulation is still very common. Whether due to incompetence or to outright fraud by the installers, installation problems are often missed, because little inspection is done to verify workmanship at the time of installation.

Problems include installers failing to account for settling of the insulation over time, leaving gaps and otherwise improperly installing batts, or even fluffing up blown insulations to make it appear that the proper amount has been applied. The problem is compounded by the fact that insulation manufacturers’ coverage charts, which dictate how much of their insulation is needed to achieve a given R-value over an area, often stretch the material too far to achieve the claimed R-values.

Consider choosing a reputable installer who will guarantee that the installed insulation achieves the R-value promised, and have an inspection of the work done, preferably by an independent inspector using a thermal-imaging camera, to verify the R-value after the job is complete. Also expect to pay more for a quality job. Unscrupulous contractors can charge less, because they skimp on both the materials and the time needed to do a proper job.

Foam insulation comes in either rigid sheets or spray. Rigid foam insulation generally has a higher R-value per inch than fiber insulation, because it uses HFCs instead of air to create pockets or bubbles in the foam sheet, thereby achieving values from R-3.6 (expanded polystyrene) to R-7.7 (isocyanurate). Rigid foam insulation is also easy to install with nails or glue. Its cost per unit R, however, is much higher than that of fiber.

Sprayed-in foam can be used in open or closed cavities as well as around ducts or pipes that pass through the building envelope. Low-density urethane spray foams can achieve up to R-11 per inch, though most foams are rated much lower, with values around R-4 to R-6. Like wet cellulose, spray foams are effective at sealing out drafts.

Care should be taken in selecting rigid foam insulation, as it can contribute to insect problems. Carpenter ants and termites will tunnel through polystyrene and polyisocyanurate foams to either create nesting cavities or to create a protected passage to wood inside a building. To combat this problem, one company has added a boric acid insect repellant to its foam insulation. Testing to date has shown the treatment to be fairly effective in keeping insects away.

Reflective insulation is different from the other kinds in that, instead of reducing conductive heat flow, it reduces radiant heat flow. When an air gap exists in a building’s shell, heat moves across the gap via infrared radiation—the same kind of radiation one feels from a campfire. The amount of radiant heat transfer depends on the temperature difference between the two surfaces, the emissivity of the warmer surface, and the absorptivity of the cooler surface. If used properly, reflective materials—single-sheet radiant barriers or multiple-layer products like reflective bubble-pack insulation—can significantly slow this radiative heat transfer by reducing the warm surface’s emissivity or increasing the cool surface’s reflectivity (the latter effectively reduces absorptivity). Reflective insulation must be adjacent to an air gap to be effective; otherwise, heat will simply conduct through to the next solid layer. A single layer of reflective foil next to an air space can provide an equivalent R-value of over R-3 in a wall system, and as much as R-8 in a floor-joist application where radiant heat flows downward. Reflective foils without an air space have an equivalent R-value of 0.

Manufacturers’ claims for the R-values of reflective insulation need to be examined closely, because the R-value can change depending on where the insulation is used. For example, in floor joist spaces above an unheated basement, convective heat losses are minimal, as the warm air will stay near the floor. As a result, radiant transfer is the primary method of heat loss, and thus a single reflective barrier can have an equivalent R-value of R-8. In a ceiling joist application, the warm air will rise away from the conditioned space, instead of into it, and so convection will be the primary method of heat loss. In this case, reflective insulation will have little effect in stopping heat loss and should not be used in place of fiber or foam insulation. A single layer of reflective insulation next to an air space in a wall can have an equivalent R-value of around R-3.

How to make the best choice
this section

Evaluate the area to be insulated. Accessibility to the area needing insulation will often be the first determining factor for choosing what type of insulation to use. New construction obviously allows for more options than an insulation retrofit, as the spaces needing insulation can be more easily reached. Table 1 serves as a general guide to where each type is commonly used.

Table 1: Typical locations for insulation types
Rigid foam insulation is applied on the surface of the wall; all other insulation is installed in the wall cavity. To install dry fiber in a retrofit, one or more holes must be cut in the wall. For wall retrofits, spray foam insulation is used to seal around pipes or other items that break through the wall or to seal the connection to the attic, and usually not to fill the wall cavity.

Available space for the insulation also affects the choice. For example, to create an R-14 barrier using isocyanurate rigid foam, which has an R-value of 7 per inch, you’d need only two inches of space in which to fit the insulation. To achieve this level of insulation using fiberglass would be much cheaper; however, it would require about four and a half inches of space to accommodate it, which may not be available in a given circumstance.

Perform a cost-benefit analysis. A cost-benefit analysis will help to determine the most cost-effective type of insulation to use and what the ultimate R-value of the building envelope should be. The selection will vary according to the local climate and is affected by the law of diminishing Returns. This law says that each additional unit of R-value contributes less energy savings than the previous one (Figure 2). The effect can be seen by looking at the U-value curve, which quickly flattens as R-values continue to climb. In practical terms, this means that adding R-10 insulation to a wall that already has R-40 insulation will save very little additional energy. In deciding on the ultimate R-value of the building envelope, it is also important to remember that many communities mandate minimum R-value levels.

Figure 2: The law of diminishing Returns
While high R-values sound attractive, the real effect of insulation—the U-value—diminishes with each additional inch of insulation. For example, an insulated 2x4 wall has an R-value of 13 and a U-value of .077. Upgrading to a 2x6 wall adds 5 points of R-value (18-13) but only drops the U-value by .022 (.077-.055). Adding another 5 points of R-value would lower U-value even less—by only .011.

Consider environmental and health factors. In 1994, the National Toxicology Program listed fiberglass as a suspected carcinogen. Fiberglass is potentially more dangerous in loose-fill form, as airborne fibers are more easily produced by handling it than when handling batts. It also uses phenol formaldehyde as a binder. Phenol formaldehyde is a pollutant both in the manufacturing stage and in buildings, because it continues to off-gas from the insulation into the surrounding spaces for several years. One company has developed a potentially safer type of fiberglass whose fibers are laminated together without the use of a binder. These fibers are actually stronger and less likely to break and form airborne respirable fibers than is fiberglass containing formaldehyde. The Greenguard Environmental Institute provides an indoor-air quality certification for numerous building materials, including insulation. You can also find a list of certified insulation products on Greenguard’s web site.

Cellulose insulation is made from recycled newspaper. Some concerns have been raised about the health risks of ink residue, but the boric acid additive that is used as a fire retardant and vermicide is generally considered safe.

Chlorofluorocarbon (CFC)-blown rigid foams have been replaced with alternative foams that use hydrochlorofluorocarbons (HCFCs) and, increasingly, HFCs because of the damage that CFCs do to Earth's protective stratospheric ozone layer. Though HCFCs are not as damaging to the ozone as CFCs, they still have a negative effect and are slated for elimination over the next two decades. HFCs have zero ozone-depletion potential.

What’s on the horizon?
this section

The best available insulation products have a maximum R-value of about R-11 per inch. Several new insulation technologies exist that have an R-value of 20 or more, but they have not been developed as building insulation products. They include gas-filled panels, vacuum insulation panels, and aerogels.

Gas-filled panels contain multiple pockets of sealed polymer film filled with low-conductivity argon, krypton, or xenon gas, which have R-values per inch of 7.2, 12.4, and 20 respectively. Vacuum insulation panels use a vacuum held between two gas-impermeable layers of metal to create R-values of 25 to 40 per inch. Aerogels are low-density solids that resemble wisps of frozen smoke. They are made most commonly from silica and offer R-values of 15 to 35 per inch. All three of these are currently used in appliances such as ovens and refrigerators, but they are too expensive to compete with traditional building insulations. One company, however, has developed a granulated transparent aerogel that is used in specialty skylights and windows with R-values of 8 to 20.

Who are the manufacturers?
this section
Neither this list nor any mention of a specific vendor or product constitutes an endorsement or recommendation by E Source, nor does any content the Business Energy Advisor constitute an endorsement or recommendation, explicit or otherwise, of your service provider’s various technology-related programs.
Content last reviewed: 
01/16/2018
E Source Business Energy Advisor

Your one-stop source for actionable advice on proven business energy management strategies. The E Source Business Energy Advisor (BEA) is a library of information that integrates with your existing website and provides sector-specific energy advice for a wide variety of business types and technologies. By providing this valuable information on your website, you can improve engagement with your business customers, help them make the case for energy efficiency, and drive them to your efficiency programs. BEA also serves as a valuable resource for account managers, business contact center representatives, and demand-side management program managers.